Aluminium windows and doors

Millennium RF with BT Door system

A fire-resistant door, classified EI₂60 – C5, with a thermal break.

Section through the CORTIZO Millennium FR door system, official manufacturer image

Millennium RF is the only door in the set of systems examined here that handles fire compartmentation. It is classified EI₂60 – C5: 60 minutes of fire resistance, with integrity and insulation, plus a self-closing device verified over 200,000 cycles.

The resistance comes from the insulating materials in the chamber of the profiles and from the expanding, biosoluble intumescent gaskets fitted around the glass. The system takes junctions with fixed lights, panic hardware, automatic closers and handles or hinges approved for the fire situation.

It is the only data sheet in the whole set written in Romanian.

Request a quote for Millennium RF

At a glance

The values that decide the choice

Fire resistanceEI₂60 – C5
Cycles200.000 (C5)
Uwfrom 1.4 W/m²K
Profile section80 mm

Specifications

The data from the official data sheet

Millennium RF with BT Door system

Flush, square profiles of 80 mm section and 2.2 mm thickness, with a 35 mm thermal break. The 60 minutes of fire resistance are obtained through the insulating materials in the chamber of the profiles and through the intumescent gaskets around the glass.

Section through the CORTIZO Millennium FR door system, official manufacturer image

Characteristics

Fire resistance
CLASS EI₂60 – C5
Thermal transmittance
Uw from 1.4 W/m²K
Glazing
maximum glazing space 48 mm
Sound insulation
maximum Rw = 38 dB
Frame sightline
80 mm
Leaf sightline
80 mm
Profile thickness
door 2.2 mm
Polyamide bar
35 mm
Thermal barrier
35 mm
Maximum dimensions / leaf
W 1,600 mm × H 2,800 mm
Maximum weight / leaf
240 kg

Classes achieved in testing

Test standards
EN 1364-1:2000 and EN 1634-1:2010
Classification
EN 13501-2:2009+A1:2010; C5 = 200,000 test cycles
Reference test specimen
door 1.35 × 2.35 m, 1 leaf, monolithic EI60 glass 23 to 25 mm

Opening configurations

  • Inward opening: side-hung with 1 and 2 leaves.
  • Outward opening: side-hung with 1 and 2 leaves.

Finishes

  • Two-tone possible
  • Coating colours (RAL, mottled and textured)
  • Wood-effect coating
  • Antibacterial coating
  • Anodised

The CORTIZO data sheet contains an internal inconsistency: the descriptive text gives a heat transfer value of 1.1 W/m²K and a maximum glazing space of 56 mm, while the technical table on the second page gives “Uw from 1.4 W/m²K” and 48 mm. We publish the values from the technical table. For a project in which this difference matters, we ask the manufacturer for written confirmation before quoting.

Download the data sheetOfficial CORTIZO data sheet – PDF · 658 KBMillennium RF with BT Door system

The thermal transmittance values published by CORTIZO are minimum values for the system, conditional on the typology, on the dimensions of the joinery and on the glazing unit. The actual value of an assembly is established by calculation, on the configuration actually ordered.

Applications

Where it is used

From system to finished joinery

What we do with this system

Choosing the configuration

The system offers a range; the project asks for a value. We settle the version, the glazing unit and the typology from the actual requirements of the building, not from the maximum on the data sheet.

Calculation on the actual assembly

The transmittance of a window depends on the frame-to-glass ratio. We calculate it on the actual dimensions of the openings, not on the laboratory specimen.

Our own production

Cutting, machining, assembly and glazing in our own workshop in Baia Mare, on original CORTIZO profile and with hardware approved for the system.

Installation and handover

We install with our own teams, including abroad, and hand the job over with its documents. The warranty is the one published on our warranties page.

Next step

Do you want Millennium RF on your project?

Send us the window schedule or the drawings. We will come back with the right version from the family, with the thermal calculation on the actual openings, and with the price.

Request a quote