Technical guide

Double or triple glazing – which should you choose?

Triple glazing is not automatically the better choice. It adds a pane and a cavity, but also weight, less light and less solar gain. What actually changes, and the situations in which each option is the right one.

What double and triple actually mean

An insulating glass unit is a sealed package of two or three panes, separated by spacer bars and filled with an inert gas. The number in the name refers to the panes, not to the cavities.

Double glazing
Two panes with one cavity between them.
Triple glazing
Three panes and two cavities.

In a quotation the unit is written as a sequence of thicknesses and spaces — pane, cavity, pane — to which the type of gas, the low-e coatings and, where applicable, the laminating interlayers are added. Without those details, “double” or “triple” says very little: two triple units can be very different from one another.

What triple gains: thermal insulation

The extra pane and cavity reduce heat loss through the centre of the glazing, so Ug falls. That is the main reason triple glazing is chosen.

But be careful what is being compared. Ug describes the glass alone. The value for the whole window, Uw, also includes the frame and the loss along the perimeter of the glazing, and their weight increases the smaller the window is. On a small window, moving from double to triple improves Uw less than someone looking only at Ug would expect.

The second condition, often overlooked: the profile has to be able to take the unit. A triple unit is thicker than a double, and the glazing rebate of the system has a stated limit. If the system does not allow it, moving to triple means changing the system, not just the glass.

What triple loses: light and solar gain

Every pane and every low-e coating holds back part of the visible light and of the solar energy. A triple unit has one more pane and usually one more low-e coating than an equivalent double, so:

  • light transmission falls — the room receives less daylight for the same glazed area;
  • the solar factor g falls — less solar energy enters, which helps in summer but means a smaller free gain in winter.

On a north-facing façade, where solar gain is small anyway, the loss matters little. On a south-facing façade of a house designed to use the winter sun, it can matter a great deal. This is why the unit is not chosen the same way on every orientation of the same building.

Weight, and what it brings with it

Three panes weigh appreciably more than two, at the same area and the same thicknesses. The weight is not a transport detail: it is transferred into the sash, the hardware and the hinges.

  • Hardware is sized on the weight of the leaf. Above certain values, hinges and locking sets for heavy weights are required.
  • In PVC, large sashes with triple glazing require additional reinforcement, because the profile has to carry the load without deforming over time.
  • On large sliding units the weight is the very criterion that decides the system; triple glazing can push the configuration towards a higher family or towards motorisation.

This means that moving from double to triple is not a box to tick at the end: it changes the profile, the hardware, and sometimes the price by more than the difference between the two glazing units.

Noise: triple is not automatically better

This is the most widespread confusion. Acoustic insulation does not increase with the number of panes, but with the asymmetry between them and with the laminating interlayer.

A symmetrical triple unit, with three panes of the same thickness, can perform worse acoustically than a well-designed double with two panes of different thicknesses and one acoustic laminated pane. Identical panes vibrate at the same frequencies and let the noise through exactly there.

If the real problem is noise — a busy street, a railway line, an area near an airport — the unit is chosen on the declared Rw value of the configuration, not on the number of panes.

When each is worth it

Triple is worth it
In a cold climate and on buildings where heat loss is the main criterion; in houses with high energy-performance requirements; on façades with little solar gain; and where the profile system can take it without compromise.
Double remains the right choice
When daylight and winter solar gain matter; on large glazed areas where weight becomes a problem; when the existing system cannot take a thicker unit; and when the budget is better spent on an acoustic or safety make-up than on one more pane.

In the same house both can be right: triple on the cold rooms and on the north façade, double with solar control on the south, acoustic double towards the street. The choice is made room by room, not for the whole house at once.

Related pages on this site