Technical guide

Uw, Ug and Uf – what they mean and which one matters for a window

The three coefficients appear in every joinery quotation, but they do not measure the same thing. What each one means, how the value for the whole window is built up, and what to ask for so that two quotations can be compared.

What a U-value actually measures

The thermal transmittance U shows how much heat passes through one square metre of an element for each degree of difference between inside and outside. It is expressed in W/(m²K), and the rule for reading it is simple: the lower the value, the less heat the element loses.

A U-value does not describe a material but an assembly in a particular make-up. The same glass in a different unit, and the same profile with different reinforcement, give different values. This is why a coefficient quoted without the make-up it belongs to says nothing.

Ug, Uf and Uw: three areas, three values

The lower-case letter at the end tells you which part of the window the value refers to.

Ug
The glass, and only the glass. The subscript comes from “glass”. It refers to the centre of the glazed unit, without the frame and without the edge of the unit.
Uf
The frame: outer frame and sash, with everything that makes up the profile. The subscript comes from “frame”.
Uw
The whole window as an installed product: glass, frame and the junction between them. The subscript comes from “window”.

Quotations sometimes also show Ud, for doors, calculated on the same principle as Uw, and Ucw, for curtain walls, where the assembly includes mullions, transoms and infill panels.

How Uw is built up from the other two

Uw is not the average of Ug and Uf. Standard EN ISO 10077-1 calculates it as a sum weighted by area, to which the loss along the perimeter of the glazing is added:

Uw = (Ag × Ug + Af × Uf + lg × ψg) / (Ag + Af)

Ag is the glazed area, Af the frame area, lg the length of the glazing perimeter, and ψg the linear thermal bridge along that perimeter.

The ψg (psi) term is the one most often left out of the conversation. It describes the heat that escapes at the edge of the glazed unit, where the glass sits in the rebate and where the spacer bar is. A spacer of low conductivity, called “warm edge” in the documentation, reduces this term without changing either Ug or Uf.

The practical consequence: two windows with the same glass and the same profile can have different Uw values if the spacer differs.

Why the same window has more than one Uw

Because Uw depends on geometry. In a small window the frame takes up a large share of the area and the glazing perimeter is long relative to the glazed area; the weight of Uf and ψg increases, so Uw moves towards the frame value. In a large window the glass dominates and Uw falls towards Ug.

This is also why manufacturers publish values for a reference window with stated dimensions. That value is not the value of your window: it is the value of a standard element, useful for comparing systems with each other.

A second consequence: a window with several sashes or with a central mullion has more frame for the same structural opening, and therefore a poorer Uw than a fixed light of the same size.

What to ask for in a quotation

For two quotations to be comparable, the values have to be comparable. Four things make the difference:

  • Uw for the actual size of the window in the project, not just the catalogue value of the system.
  • The full make-up of the glazing, not just “triple glazing”: the thicknesses, the cavities, the gas and the low-e coatings.
  • The type of spacer bar, because it determines the ψg term.
  • The standard the calculation follows, so that you know both quotations were calculated the same way.

If a quotation gives a single figure, with no size and no make-up, that figure cannot be compared with anything.

What Uw does not tell you

Uw describes a single property: heat loss. A well-chosen window is judged on several axes, and they can call for solutions that pull in different directions.

The solar factor g
How much solar energy comes in through the glazing. A low value keeps heat out in summer, but also reduces the free gain in winter.
Light transmission
How much visible light passes through. Solar-control coatings reduce it, sometimes noticeably.
Acoustic insulation Rw
It is achieved with panes of different thicknesses and with special interlayers, not necessarily with the same unit that gives the best Ug.
Burglar resistance
It is classified separately, in RC classes, and depends on the hardware, the glazing and the way the window is fitted.

On a real project these requirements are weighed against one another. The right choice is not the lowest figure on paper, but the make-up that answers the requirements of the building.

Related pages on this site